Polyisocyanurate PIR Boards

product description

PIR insulation boards are rigid insulation material, produced through the reaction of isocyanate and polyether. It has better fire resistance performance than polyurethane foam. In addition, PIR foam has low thermal conductivity, wide service temperature range, and excellent dimension stability properties. It can be cut into a pipe cover and flat or board easily. ZES PIR foam insulation meets the standards of ASTM C591 and CINI 2.7.01.

Properties

Item

Unit

Technical   Data

Testing   Method

Density

kg/m3

≥40

ASTM D1622/

ISO 845

 

Thermal Conductivity at Ambient Temperature

 (180 Days Aged )

W/(m·K)

≤0.035 (+100℃)

ASTM C177

≤0.029 (+50℃)

≤0.025 (+10℃)

≤0.024 (0℃)

≤0.023(-50℃)

≤0.022(-100℃)

≤0.017 (-150℃)

≤0.016 (-170℃)

Compressive Strength

(All Directions)

+23℃

kPa

≥200

ASTM D 1621

-165℃

≥280

Tensile Strength

(All Directions)

+23℃

kPa

≥320

ASTM D 1623

-165℃

≥265

Flame Spread Index


﹤25

ASTM E84

Oxygen Index


≥30

GB/T 2406.2

Water Absorption by Vol

%

≤5

ASTM D2842

Water Vapor Permeability

ng/(Pa·s·m)

≤5.5

ASTM E96

Closed Cell Content

%

≥95

ASTM D6226

Linear Thermal Expansion Coefficient

m/(m·K)

≤70×10-6

ASTM D696

PH Value


5.5-7

ASTM C871

Chloride and Fluoride Content


Meet the Standard Specification of Thermal   Insulation Materials for Use over Austenitic Stainless Steel

GB/T 11835

Elasticity Modulus

MPa

≤16

ASTM D1623

Service Temp

-196~+120


Product Application

It is a kind of ideal organic thermal insulation materials applied at low temperature, result from its low thermal conductivity, lightweight, anti-vibration and compatibility. It is widely used as insulation in oil refinery, chemical, ethylene and fertilizer industries, as well as refrigeration house and LNG systems.                            

Packing and Storage

(1) Store in a dry, lightproof, shady, and ventilated place, keep away from heat source and protect from sun exposure.

(2) Inner Packing: Polythene bags Outer Packing: Cartons

Application and Cautions

(1) PIR shall be handled gently, avoid rolling, collision and heavy pressure during moving.

(2) When applied to pipe and equipment insulation, PIR shall be fastened with glass fiber tape or steel band.

(3) Cut it with saw during application.

Inquiry
  • captcha